XM-A3B2-0409D
XR-A3B2-0409D RoHS

Switch, PE42520C-Z [PCB: 0298]
Recommended Bias Controller: XM-C3T4-0409D-SP
Configurations
                    Unit of Measure
                    
               
        
            | Low Freq | N/A 0.009 MHz | 
| High Freq | N/A 13000 MHz | 
| IL | N/A 2 dB | 
| P1dB | N/A 39 dBm | 
| IP3 | N/A 66 dBm | 
| Bias Instruction | N/A
                                                                                        Power-up Sequence 1. Apply -VSS = -3.4V (Note 1,2) 2. Apply +VDD = +3.4V 3. Apply Control Voltage to LS and CTL (0V = LOW, +3.3V = HIGH) 4. Apply the RF input signal Power-down Sequence 1. Turn off the RF input signal 2. Adjust LS and CTL to 0V 3. Adjust -VSS to 0V 4. Adjust +VDD to 0V Note: 1. Normal mode: Connect VSS to GND (VSS = 0V) to enable internal negative voltage generator. 2. Bypass mode: Supply –3.4V to VSS to disable internal negative voltage generator. | 
|  | N/A | 
| RoHS | N/A XR-A3B2-0409D | 
 
              