XM-C7R6-0404D
XR-C7R6-0404D RoHS



Amplifier, CMD242K4 [PCB: 1704]
Recommended Bias Controller: XM-C7Y6-0404D-SP

Configurations

Unit of Measure

Product Page

N/A Qorvo

Spec Sheet

N/A CMD242K4

Low Freq

N/A 50 MHz

High Freq

N/A 40000 MHz

Gain

N/A 10.5 dB

NF

N/A 5 dB

P1dB

N/A 17.5 dBm

IP3

N/A 25 dBm

Bias Instruction

N/A Power-up Sequence
1. Apply VG1 = -2.0V
2. Apply VDD = 8.0V
3. Adjust VG1 more positive until IDQ reaches 100mA
Note: VG1 ~ -0.32V, Do not exceed 0.0V
4. Apply the RF input signal
Note:

RF power can be applied at any time.

Power-down Sequence
1. Turn off the RF input signal
2. Adjust VG1 to -2.0V
3. Adjust VDD to 0V
4. Adjust VG1 to 0V

Note: VG2 is left open for self-bias, optional for gain control

RoHS

N/A XR-C7R6-0404D