Unit of Measure
Product Page |
N/A ADI |
Spec Sheet |
N/A
HMC-ALH444 |
Low Freq |
N/A 1000 MHz |
High Freq |
N/A 12000 MHz |
Gain |
N/A 17 dB |
NF |
N/A 1.75 dB |
P1dB |
N/A 19 dBm |
IP3 |
N/A 28 dBm |
Bias Instruction |
N/A
Power-up Sequence
1. Apply VG1 = -1.0V 2. Apply VDD = 5.0V 3. Apply VG2 = +1.5V 4. Adjust VG1 more positive until IDQ reaches 55mA Note: VG1 ~ -0.5V, Do not exceed 0.3V 5. Apply the RF input signal Power-down Sequence 1. Turn off the RF input signal 2. Adjust VG1 to -1.0V 3. Adjust VG2 to 0V 4. Adjust VDD to 0V 5. Adjust VG1 to 0V |
RoHS |
N/A XR-B8U6-0404D |