Configurations
Low Freq |
N/A 0.009 MHz |
High Freq |
N/A 13000 MHz |
IL |
N/A 2 dB |
P1dB |
N/A 39 dBm |
IP3 |
N/A 66 dBm |
Bias Instruction |
N/A
Power-up Sequence 1. Apply -VSS = -3.4V (Note 1,2) 2. Apply +VDD = +3.4V 3. Apply Control Voltage to LS and CTL (0V = LOW, +3.3V = HIGH) 4. Apply the RF input signal Power-down Sequence 1. Turn off the RF input signal 2. Adjust LS and CTL to 0V 3. Adjust -VSS to 0V 4. Adjust +VDD to 0V Note: 1. Normal mode: Connect VSS to GND (VSS = 0V) to enable internal negative voltage generator. 2. Bypass mode: Supply –3.4V to VSS to disable internal negative voltage generator. |