XM-C7D8-0404D
XR-C7D8-0404D RoHS

Amplifier, CMD298C4 [PCB: 0316]
Recommended Bias Controller: XM-B4V1-0404D-SP
Configurations
                    Unit of Measure
                    
               
        
            
                                                                                Low Freq | 
                                                                        N/A 17000 MHz | 
                                                                                High Freq | 
                                                                        N/A 25000 MHz | 
                                                                                Gain | 
                                                                        N/A 27 dB | 
                                                                                NF | 
                                                                        N/A 1.4 dB | 
                                                                                P1dB | 
                                                                        N/A 8 dBm | 
                                                                                IP3 | 
                                                                        N/A 19 dBm | 
| 
                                                                                 | 
                                                                        N/A | 
                                                                                Bias Instruction | 
                                                                        
                                                                            
                                                                                    
                                                                                        N/A
                                                                                        Power-up Sequence
 1. Apply VDD = +3.0V 2. Apply VGG = +1.5V Verify IDD = 27mA 4. Apply the RF input signal Power-down Sequence 1. Turn off the RF input signal 2. Adjust VGG to -0V 3. Adjust VDD to 0V Note: RF power can be applied at any time.  | 
                                                    
                                                                                RoHS | 
                                                                        N/A XR-C7D8-0404D |